10 KVA Escort Powerlux Generator
- Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
- Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
- Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
Description
10 KVA Escorts Silent Diesel Generator
| Power | 10 kVA |
| Material | MS |
| Brand | Escorts |
| Application | Industrial |
| Cooling System | Liquid Cooling |
| Noise Level | Silent or Soundproof |
| Engine Model | G12-II |
| Dimension | 1530 x 930 x 1160 mm (L x B x H) |
| Fuel Tank Capacity | 80 Liter |
| No Of Cylinders | 2 |
| Weight | 655 kg |
| Voltage | 415 V |
| DG Model | ELG 10 |
| Rated Current | 43 Amps at 230 V, 14 Amps at 415 V |
| Brake Horsepower | 18 BHP |
| Aluminium Cable | 2C-25/3.5C-16 Sq. mm. |
| Aspiration | Natural |
Other Essentials:
- Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
- Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
- Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
- Put on only those equipment’s which you want to run on the Powerlux Silent Generator.
- Go near the distribution box where you’ll find four colored cables; Red, Yellow, Blue & Black.
- Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
- Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
- Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
- After putting the clamp meter around the cable; turn off and on the heavy machines/equipment’s for better calculation. Also always select a rating 20% higher to your load for long term usage.
- AII of the above silent genset range is made to perform at 1500 rpm.
- Rated current output is at 100% load.(0.8 Power Factor).
- Weight mentioned is approximate.
- Product innovation is a continuous process; hence data given is subject to change without any prior notice.
- Detailed technical specification sheet separately available for each rating in soft copy.