25 KVA TATA Powerlux Generator
- Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
- Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
- Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
Description
25 kVA Tata Powerlux Silent Diesel Generator
Duty |
Prime |
Starting System |
12V |
Model |
4SP |
No. of Cylinders |
4 |
Aspiration | Turbocharger Intercooler |
Lube oil change period | 500 |
Class of Insulation | Class H |
Voltage (V) | 215 V / 415 V |
Power Factor | 0.8 (lagging) |
Maximum unbalanced load across phases | Up to 25% |
Power Rating kVA | 25 |
Power Rating kWe | 20 |
Current | 108 / 35 Amp |
RPM / Frequency | 1500 RPM / 50 Hz |
DG Set Noise at 1 meter | < 75 dBA |
Rated Power (kW) | 32 |
Horse Power | 43 |
Performance class | ISO 8528 |
Governing class | G3 |
Displacement | 2956 |
Bore X Stroke | 97 x 100 |
Rated Speed | 1500 |
Ambient Temperature Range | -10 to 50 deg C |
Fuel System | CRDI |
Total lubrication system capacity (litre) | 8.3 |
Total coolant capacity including engine & radiator (litre) | 12 |
DEF Capacity (litre) | NA |
Fuel | High Speed Diesel |
Lube oil | CK4 15W40 |
Enclosure type | IP23 |
Other Essentials:
- Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
- Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
- Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
- Put on only those equipment’s which you want to run on the Powerlux Silent Generator.
- Go near the distribution box where you’ll find four colored cables; Red, Yellow, Blue & Black.
- Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
- Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
- Select your kVA from the above given ampere chart and see under which rating your requirement falls.
Note:
- After putting the clamp meter around the cable; turn off and on the heavy machines/equipment’s for better calculation. Also always select a rating 20% higher to your load for long term usage.
- AII of the above silent genset range is made to perform at 1500 rpm.
- Rated current output is at 100% load.(0.8 Power Factor).
- Weight mentioned is approximate.
- Product innovation is a continuous process; hence data given is subject to change without any prior notice.
- Detailed technical specification sheet separately available for each rating in soft copy.