45 KVA Tata Powerlux Generator

  • Engines are tested as per IS 10000 standards
  • Superior Quality alternators are used confirming to IS13364, IS4722 & BS5000 standards
  • Technologically advanced control panels with deep sea/ Procom controller
  • Heavy, Robust and sound efficient DG gets confirming to CPCB-II norms & rule 95 of environment protection of GSR no of 771 (E) & GSR 232 (E)
Category:

Description

45 kVA TATA Silent Diesel Generator, 3 Phase

 

Duty Prime
Controller Type DSE
Starting System 12V D.C.
Weight (Kg) (Approx.) 1295
Noise @75% load (dBA) <75Db @ 1m
Dimension (LxWxH)(mm) (with duct) 2850X1150X2000
Dimension (LxWxH)(Feet)(with duct) 9.2X3.6X6.6
Battery Type 12 Volt
Battery output (mAH) 90 or more
Battery Make Exide Genplus or Amaron
Silencer Dia. (mm) 257
Exhaust Pipe Dia. (Inch) 3
Base Body Type/Thickness(mm) Sheet/3&4
Body Sheet Thickness (mm) 1.2
PU Foam Thickness (mm) 40
Fuel Tank Capacity (Liters) 162
Model 497TC75
Make TATA MOTORS LIMITED
Speed(RPM) 1500
Cubic Capacity (L) 3.784
BHP (gross) 67
No. of Cylinders 4, in-line
Bore (mm) 97
Stroke (mm) 128
Compression Ratio 17.5:01
Aspiration TCIC
Cooling System Liquid Cooled
Governing Mechanical, Class A1
Fuel Type HSD
Oil Capacity (L) 10
Oil Grade CI4 or +
Lube oil change period 500 hours/6 Month
Current at 100% (A) 108/35
Make & Type Deepsea or equivalent
No. of Bearings Single
Class of Insulation H
Voltage Variation (%) +/- 1%
Enclosure Confirmation IP23
Phase 1/3
Coupling Details SAE2/10″
Voltage (V) 230/415
Frequency (Hz) 50
Power Factor 0.8
Maximum unbalanced load across phases Less than or equal to 25%
Make Deepsea or equivalent
Sheet type CRCA
Sheet thickness (mm) 1.6
MCB/MCCB MCB/MCCB
Pole/ Rating 1Phase (Amps.) 2 Pole / 200 Amp
Pole Rating 3 Phase (Amps.) 3 Pole / 63 Amp
Conductors suitable capacity of incoming and outgoing terminals Yes
Indicating lamps for “Load ON” and “DG Set Running” Yes
MCB/MCCB with overload and short circuit protection Yes
Shutdown for O/U Voltage, Overload, O/U Hz, Battery Charging failure, Belt Break, Emergency Stop, Low Fuel, Radiator water level, HWT, LLOP Yes
Display for Voltage Phase-Nutral, Frequency, Current Oil Pressure, Water Temp., RMP, Running Hrs, Service Due Hrs, Battery Volt., Fuel Level in % Yes
LED & Alarm for O/U Voltage, Overload, O/U Hz, Battery Charging failure, Belt Break, Emergency Stop, Low Fuel, Service Due, Radiator Water Level, HWT & LLOP Yes

 

Other Essentials:

  • Engines are tested as per IS 10000 standards
  • Superior Quality alternators are used confirming to IS13364, IS4722 & BS5000 standards
  • Technologically advanced control panels with deep sea/ Procom controller
  • Heavy, Robust and sound efficient DG gets confirming to CPCB-II norms & rule 95 of environment protection of GSR no of 771 (E) & GSR 232 (E)


How to Calculate Load:

  • Put on only those equipments which you want to run on the Powerlux Silent Generator.
  • Go near the distribution box where you’ll find four colored cables; Red, Yellow, Blue & Black.
  • Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating. Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
  • Select your kVA from the above given ampere chart and see under which rating your requirement falls.


Note:

  • After putting the clamp meter around the cable; turn off and on the heavy machines/equipments for better calculation. Also always select a rating 20% higher to your load for long term usage.
  • All of the above silent genset range is made to perform at 1500 RPM
  • Rated current output is at 100% load. 0.8 power factor
  • Weight mentioned is approximate
  • Product innovation is a continuous process; hence data given is subject to change without any prior notice.
  • Detailed technical specification sheet separately available for each rating in soft copy

Reviews

There are no reviews yet.

Be the first to review “45 KVA Tata Powerlux Generator”

Your email address will not be published. Required fields are marked *